Jefferson Street Drawbridge 287.9 ILW Emergency Outage

Terry,
Please pass the word: Jefferson Drawbridge is currently inop. A boiler system leak caused flooding in the bridge’s electrical room. System components were severely damaged by fire resulting from shorting associated with the flooding.

There is no redundant operation system to facilitate drawspan opening.

ComEd Power Company is enroute to the bridge to secure power and make the site safe for full damage assessment. IDOT is looking into securing replacement ops units. If replacement components are not readily available, I have instructed IDOT to bring in a crane and lift the drawpans manually. If manual opening is required, IDOT will then lock the bridge in the open to navigation position until repairs can be completed.

Peter J. Sambor, M.P.A.
USCG Bridge Management Specialist
1222 Spruce Street, Suite 2.102D
Saint Louis, MO 63103
(314) 269-2380

Email from Terry Bass

Blessey Marine